Table 1 Energy density of transmitted light as packaging films by intense pulsed light treatment

(unit: W/m2)
Wave Length UV-C (220-280 nm) UV-B (280-315 nm) UV-A (315-400 nm) RAD (400-1,050 nm)
Packaging film materials PE Control 3.567±0.0041)a 4.054±0.022a 1.659±0.005ab 2.453±0.014a
30 μm 3.193±0.016b 4.022±0.038ab 1.661±0.010ab 2.456±0.005a
40 μm 3.163±0.031bc 3.995±0.021ab 1.663±0.006ab 2.455±0.017a
50 μm 3.108±0.047c 3.984±0.036b 1.654±0.004a 2.455±0.022a
70 μm 2.947±0.052d 4.019±0.044ab 1.667±0.006b 2.476±0.013a

PP Control 3.567±0.004a 4.054±0.022a 1.659±0.005a 2.453±0.014ab
30 μm 3.258±0.014b 3.990±0.024b 1.652±0.038a 2.478±0.017a
40 μm 3.147±0.024c 4.028±0.033ab 1.657±0.008a 2.458±0.008ab
50 μm 3.110±0.026c 4.018±0.021ab 1.665±0.004a 2.470±0.016a
70 μm 3.003±0.047d 4.015±0.044ab 1.661±0.006a 2.440±0.013b

OPP Control 3.567±0.004a 4.054±0.022a 1.659±0.005ab 2.453±0.014a
30 μm 3.200±0.031b 4.015±0.025a 1.662±0.004a 2.455±0.015a
40 μm 3.168±0.037b 4.006±0.024a 1.652±0.002b 2.471±0.013a

PET Control 3.567±0.004a 4.054±0.022a 1.659±0.005a 2.453±0.014a
100 μm 0.065±0.001b 0.651±0.010b 1.650±0.005ab 2.446±0.010a
200 μm 0.057±0.002c 0.517±0.010c 1.648±0.004b 2.444±0.008a
1)Mean±SD
a-dMeans are significantly within the same column at p<0.05 by Duncan’s multiple range test.
Treatment condition: 1,000 V, 5 pps, distance: 1.5 cm